Engineering & Dough Rheology Notes

Small-batch instrumentation experiments: PID thermal enclosures, hydration telemetry, and deterministic sensor sampling.

October 18, 2026 · Embedded & Control

Compensating Thermal Zero-Drift on 24-bit Load Cells

Long-horizon mass tracking during 36-hour cold fermentation suffers from ratiometric bridge drift when ambient temperatures cycle between 4 °C and 22 °C. Pairing an SHT45 reference sensor with a two-point polynomial lookup table keeps residual error below 0.12 g.

September 04, 2026 · Thermal Modelling

Feed-Forward PWM Scheduling for Insulated Proofing Boxes

Standard hysteresis relays overshoot high-hydration alkaline noodle dough targets in small 35 L enclosures. Switching to a dead-time-compensated PI loop on an RP2040 eliminates thermal ringing without stressing solid-state switches.

July 22, 2026 · Instrumentation

Reference Calibration Fixture & Binary LUT Format (v2)